Analab EasyTrace & EasyTrace CleanRinseDry

Acid Vapor Labware Cleaning Systems

EasyTrace Systems provide high purity vessel cleaning without requiring ultrapure acids. They safely operate unattended with low operating costs and help produce low repeatable blank levels.

Better Sample Preparation = Better Results

  • Take the guesswork and manual steps out of your labware cleaning process for trace metal analysis with the automated EasyTrace systems
  • Analab’s unique vapor distillation process cleans your glass and plastic laboratory vessels safely and efficiently with small volumes of acid in a closed system
  • EasyTrace delivers significant costs savings by distilling reagent-grade acids and automating a typically labor-intensive process
  • The EasyTrace system automates the acid cleaning phase, while the addition of the CleanRinseDry (CRD) capability fully completes the vessel cleaning process with the automated rinsing and drying of your labware
  • No operator contact with corrosive acids with enclosed EasyTrace and EasyTrace CRD systems
EasyTrace System
EasyTrace System

EasyTrace Models

EasyTrace provides automated acid vapor cleaning of laboratory vessels

  • Operates with remotely located Analab regulator (110 V and 208-240 V models)
  • Utilizes small volumes of acids (300-500 mL) such as HNO3, HCL, HF
  • Cleaning acid can be manually exchanged with water to provide steam rinsing

EasyTrace with CleanRinseDry (CRD) fully automates the Cleaning, Rinsing and Drying steps

  • Supports a dual acid capability to allow automated acid vapor cleaning with two different acids
  • Provides a steam rinse cycle with heated water
  • Completes the process with a heated drying cycle
EasyTrace System
EasyTrace System
EasyTrace with CRD Model
EasyTrace with CRD Model

Models

How It Works

  • Closed-environment fluoropolymer EasyTrace enclosure for laboratory vessels equipped with a heated zone on the bottom of the unit
  • Small quantity of reagent grade acid (or water) is heated to create high-purity vapor that rises up into vessels
  • Vapors cool and condense on vessel walls, dissolving contaminants on the surfaces and pores of the vessel walls
  • Condensed droplets containing impurities drain down the vessel walls and return to the heating tray base
  • All contaminants stay in the base of the system; only clean acid vapors or steam reaches the vessels
  • In base EasyTrace system exchanges of acid and water from the base is performed manually when needed
  • EasyTrace with CleanRinseDry (CRD) provides automated switching between acids, water, and a final drying step to fully automate the vessel cleaning process
How It Works

CRD Automation

The EasyTrace CRD (Clean/Rinse/Dry) completely automates the labware cleaning process. A fully automated controller fills/empties the cleaning chamber with timed operating temperature cycles, then dries the chamber and contents after the cleaning and rinse steps are completed.

CRD Automation

EasyTrace Accessories

A variety of accessories are available to support vessels, caps and pipet tips inside the EasyTrace and EasyTrace CRD systems.

All Systems Equipped with Tray and Removable Rods
All Systems Equipped with Tray & Removable Rods
Square Tray with Top Tray
Square Tray with Top Tray
Outer Diameter Vessel Holder
Outer Diameter Vessel Holder
P’Tips Racks for Cleaning Various Pipette Tip Sizes
P’Tips Racks for Cleaning Various Pipette Tip Sizes


EasyTrace S35 CRD

Part No.: ET-S35-CRD-1V / ET-S35-CRD-2V

EasyTrace with Clean Rinse Dry System (CRD) is completely self-contained so the operator is not in contact with the reagent.
345 x 345 x 235 mm capacity.

Available configurations:

  • 110V - (#ET-S35-CRD-1V)
  • 208-240V - (#ET-S35-CRD-2V)

EasyTrace S35

Part No.: ET-S35-1V / ET-S35-2V

EasyTrace S35. Requires manual filling and draining.
345 x 345 x 235 mm capacity.

Available configurations:

  • 110V - (#ET-S35-1V)
  • 208-240V - (#ET-S35-2V)

Middle Plate for EasyTrace S35

Part No.: ETX-MP-S35
PTFE Middle Plate, for use with EasyTrace S35.

Outer Diamter Vessel Holder for EasyTrace S35

Part No.: ETX-OD-S35
Outer Diameter vessel holder, for use with EasyTrace S35.

Additonal Tray and Stabilizing Rods for EasyTrace S35

Part No.: ETX-BASE-80R-S35
An additional PTFE base plate, and convenient 120mm tall rods (qty 80). Allow you to prepare a second set of vessels to be washed in advance.

Stabilizing Rods

Convenient rods (qty 48) in PTFE allow you to stabilize your vessels on the plate.

Available options:

  • Additional rods – 120 mm height (#ETX-48R-120)
  • Additional rods – 160 mm height (#ETX-48R-160)
  • Additional rods – 210 mm height (#ETX-48R-210)

Pipette Tips Rack

Pipette tips racks allows you to easily and efficiently clean multiple sizes inside the EasyTrace unit.

Available options:

  • Pipette tips rack to hold 200 uL (#ETX-PR-200)
  • Pipette tips rack to hold 1000 uL (#ETX-PR-1000)
  • Pipette tips rack to hold 5000 uL (#ETX-PR-5000)
  • Pipette tips rack to hold 10000 uL (#ETX-PR-10000)